Avtron Load Bank Instruction Manual

  
Avtron Load Bank Instruction Manual Rating: 3,5/5 8944 reviews
Avtron Load Bank Instruction ManualOperating

56.00 [1422.00] (400 KW) 47.50 [1207.00] (200-250 KW) CONTROL PANEL 5.25 [133.00] LIFTING EYES 15.75 [400.00] 1.75 [44.00] 1.75 [44.00] 0.562 [15.00] DIA 4 HOLES CUSTOMER LOAD CONNECTION ACCESS BOX LOAD CONNECTION PHASE BUS BARS (See detail below) GROUND STUD 3/8-16 AIR INTAKE AIR EXHAUST FORKLIFT CHANNELS 33.75 [857.00] 120V LINE CORD 2.50 [64.00] 50. Emd locomotive manuals. 25 [1276.00] GND SPECIFICATIONS: CONSTRUCTION: A rugged aluminized steel enclosure with screened inlet and exhaust openings. Two fixed and two lock- able swivel casters provide mobility. Lifting eyes, forklift chan- nels, and tie-down hooks are standard. CONTROL POWER: The Millennium Load Bank requires control power of 120 VAC, single phase, 60 Hz (control transformer optional). COOLING: The resistive elements are air cooled by an inte- grally mounted 3 phase blower (250 KW or 400 KW unit) or a single phase blower rated 120 VAC (200 KW unit).

No additional cooling period is required when load is removed. CONTROLS: The operator control panel includes a MASTER LOAD ON-OFF switch, load step ON-OFF industrial toggle switches, BLOWER ON-OFF push buttons with a BLOWER FAILURE light, and BLOWER and LOAD VOLTAGE se- lector switches (dual voltage units only). DIGITAL METERING: Avtron Advanced Digital Monitoring System (ADMS™) is provided for display of Volts, Amps, Fre- quency, and KW. ADMS™ also includes Communicator EXT™ Data Logging Software. SAFETY CIRCUITS: The Millennium Load Bank features branch circuit fusing on all load steps.

Avtron Lph100 Load Bank Manual

Vertiv VR Rack. Standardize your deployments around the world and bring them online faster with the Vertiv VR rack. Gale outboard owners manual. The Vertiv VR supports a wide variety of equipment including servers, storage, switches, routers, PDUs, UPSs, console port servers and KVM switches. He Avtron Model K875A load bank can be utilized independently or as a modular building block for. Instruction manual for important safety considerations.

Wrong voltage protec- tion, motor overload protection, overtemperature protection, and cooling air loss protection are also provided. WEIGHT: 200-250 KW unit: approx. [295 kg] 400 KW unit: approx. [360 kg] OPTIONS: • Control Power Transformer • Vinyl Storage Dust Cover • Designs for international 50/60 Hz voltages or custom DC designs are also available. Consult Factory.